Two generators in one electrosurgery unit
Bipolar and monopolar outputs are available simultaneously and work independently of each other. In addition a second monopolar output is available on a first come first served basis.
For outstanding performance in electrosurgery
TD830 bipolar and monopolar generators provide cutting and coagulation output modes; each is easy to use, giving optimal speed and precision which is essential when the minimisation of tissue damage is a priority.
Designed for ease of use
The simple clear colour coded front panel enables the user to select monopolar and bipolar modes at the touch of a button. The pull-out card in the bottom of the unit gives guidance on basic set up and fault conditions, ensuring training requirements are kept to a minimum in busy operating theatres. The front panel alarm identification will illuminate to prompt corrective action should a fault condition arise.
Safety first for the patient and operator
Eschmann have always known that safety is of key importance. As such the
TD830 electrosurgery unit has been designed to incorporate advanced safety monitors which work together to minimise the risk to the patient, surgeon and theatre staff. These include Patient Continuity, Plate Attachment (divided plates), Patient Earth, Plate Voltage and Excess Power Monitors.
Comprehensive after-sales service for peace of mind
For complete peace of mind, Eschmann after sales service department offer a comprehensive service providing the reassurance of a fast response in the unlikely event of a problem with your equipment.
| Input | |||
| Mains 230V ac, 240V ac, 220V ac, 110V ac @ 50/60 Hz | |||
Monopolar |
|||
| Nominal Load: 150-200 Ohms | |||
|
Power
|
Crest Factor
|
Open Circuit Output
Voltage (peak) |
|
| Normal Cut |
345W
|
1.9
|
1150
|
| Blend |
300W
|
3.0
|
2200
|
| Cut (specialist) |
345W
|
2.1
|
1500
|
| Pinpoint Coag. |
170W
|
5.1
|
2150
|
| Spray Coag. |
79W
|
8.7
|
4000
|
Bipolar |
|||
| Nominal Load: 100 Ohms | |||
| Coag. | high range 50W |
Variable
|
150
|
| Low range 15W |
Variable
|
230
|
|
Frequency |
|||
| Monopolar | 475kHz | ||
| Bipolar | 785kHz | ||
Safety |
|||
| Complies with Medical Devices Directive 93/42/EEC. Class 1, defibrillator proof, drip proof. |
|||
Leakage Currents |
|||
| Patient leakage (MSK) current: always less than 100 microamps to earth (ground) from all patient circuits at 230v 50Hz for the unit in normal conditions. | |||
Weight |
|||
| 14 Kg | |||
Dimensions |
|||
| 425 x 390 x 190 mm | |||
Shipping Information |
|||
| Air freight and sea freight | |||
| Case dimensions: | 659mm x 659mm x 407mm | ||
| Gross weight: | 14.5 kg | ||